Quantcast
Channel: VMware Communities : Discussion List - ESXi
Viewing all articles
Browse latest Browse all 8132

ESXi 6.5 VM Wont power up after RAID disk replacement

$
0
0

Ive got a few windows servers on ESXi 6.5. We recently had a drive go bad in a RAID 5 array and after replacement none of my VM's will start.

 

When I try to start one of the servers I get the following error:

 

Failed to power on virtual machine SERVER01. An error occurred while creating temporary file for /vmfs/volumes/59d53e71-8aef69f2-ac91-0cc47a28ed6c/SERVER01/SERVER01.vmx: The file already exists Click here for more details. - dismiss

 

More details:

 

Power On VM

Key

haTask-17-vim.VirtualMachine.powerOn-163458699

 

Description

Power On this virtual machine

 

Virtual machine

SERVER01

State

Failed - An error occurred while creating temporary file for /vmfs/volumes/59d53e71-8aef69f2-ac91-0cc47a28ed6c/SERVER01/SERVER01.vmx: The file already exists

 

Errors

An error occurred while creating temporary file for /vmfs/volumes/59d53e71-8aef69f2-ac91-0cc47a28ed6c/SERVER01/SERVER01.vmx: The file already exists

Cannot open the configuration file /vmfs/volumes/59d53e71-8aef69f2-ac91-0cc47a28ed6c/SERVER01/SERVER01.vmx.

Failed to start the virtual machine (error -18).

 

Here is the output of tail -f /var/log/vmkernal.log when I try to start the VM:

 

2020-05-01T15:25:35.662Z cpu0:67815 opID=8a693dcb)World: 12230: VC opID 14d5ca96 maps to vmkernel opID 8a693dcb

2020-05-01T15:25:35.662Z cpu0:67815 opID=8a693dcb)Config: 706: "SIOControlFlag2" = 1, Old Value: 0, (Status: 0x0)

2020-05-01T15:25:35.682Z cpu8:82139)MemSched: vm 82139: 6366: extended swap to 28160 pgs

2020-05-01T15:25:35.698Z cpu8:82139)WARNING: Res3: 3132: [type 2] resource 15 (cluster 323) on volume labeled 'datastore2' already freed by another host: This may be a non-issue

2020-05-01T15:25:35.698Z cpu8:82139)Fil3: 4229: Truncating <FD c323 r155> failed: Not found

2020-05-01T15:25:35.718Z cpu0:67858)Config: 706: "SIOControlFlag2" = 0, Old Value: 1, (Status: 0x0)

2020-05-01T15:25:40.693Z cpu8:66257)ScsiDeviceIO: 2948: Cmd(0x439509a51480) 0x1a, CmdSN 0x1e97 from world 0 to dev "naa.600605b00cd4ed702166741404255495" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x24 0x0.

 

Any help to either fix this VM or use its data to rebuild it will be much appreciated.

 

Thanks in Advance!!!

 