0 Gbps - ESXi 6.5 update 3 host not connecting to storage

$
0
0

Hello,

We have ESXi 6.5 update 3 running on Cisco B200 blades using 6248 Fabric interconnects.

We have purchased new 6454 fabric interconnects and I have moved 1 chassis and 1 blade to the new FIs for testing.

The blade/ESXi host is connecting and pinging on the network good.

However, if I try to rescan storage it takes 30 minutes and fails. If I try to reboot it takes over an hour and doesn't really attach all storage successfully.

If I unmap all storage it reboots and rescans as normal. It sees the array just fine.

 

The zoning is connected at 8 Gbps and the FIs say connected at 8 Gbps.

However, VMware says the speed is 0 Gbps. see below output.

 

I have checked compatibility lists and it seems our fnic, enic, vmware version and ucs version is all compatible.

 

Has anyone seen this?

Any help is much appreciated!

 

 

[root@kcesx9:~] esxcli storage san fc list

   Adapter: vmhba1

   Port ID: 0A3A03

   Node Name: 20:00:00:25:b5:a5:02:df

   Port Name: 20:00:00:25:b5:a1:02:df

   Speed: 0 Gbps

   Port Type: NPort

   Port State: ONLINE

   Model Description:

   Hardware Version:

   OptionROM Version:

   Firmware Version:

   Driver Name:

   DriverVersion:

 

Adapter: vmhba2

   Port ID: 0B1203

   Node Name: 20:00:00:25:b5:a5:02:df

   Port Name: 20:00:00:25:b5:b1:01:df

Speed: 0 Gbps

   Port Type: NPort

   Port State: ONLINE

   Model Description:

   Hardware Version:

   OptionROM Version:

   Firmware Version:

   Driver Name:

   DriverVersion:

==================

 

These are some of the naa's that popped up with connectivity issues.

 

naa.6001738c7c80534900000000000134a8

naa.6001738c7c8053490000000000021977

naa.6001738c7c805349000000000002204c

naa.6001738c7c805349000000000001349f

naa.6001738c7c8053490000000000013499

    

In the logs:

2020-07-06T19:19:51.900Z cpu11:65844)WARNING: HBX: 2580:Failed to cleanup VMFS heartbeaton volume5e604295-151f2b8e-871a-0025b500a516: No connection

 

2020-07-06T19:19:51.900Z cpu23:66148)ScsiDeviceIO: 3015: Cmd(0x439590d03b40) 0x28, CmdSN 0xa from world 74231 to dev "naa.6001738c7c805349000000000002204c" failed H:0x8 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.

2020-07-06T19:19:51.900Z cpu23:74231)LVM: 5953: PE grafting failed for device naa.6001738c7c805349000000000002204c:1, vol 5e6079a4-96282218-633b-0025b500a516/7688724183283841769: Timeout

2020-07-06T19:19:51.900Z cpu11:65844)WARNING: HBX: 2580: Failed to cleanup VMFS heartbeat on volume5e604295-151f2b8e-871a-0025b500a516: No connection

2020-07-06T19:19:51.900Z cpu11:65844)Vol3: 3073: Error closing the volume: No connection. Eviction fails.